FAIRCHILD M200XLR Pneumatic Volume Booster

  • Brand:
    FAIRCHILD
  • Flow Capacity (SCFM):
    In excess of 1500 (2550 m3 /hr) @ 100 psig, [7.0 BAR], (700 kPa) supply and 20 psig, [1.5 BAR], (1500 kPa) setpoint
  • Exhaust Capacity (SCFM):
    325 (552.5 m3 /hr) where downstream pressure is 5 psig, [.35 BAR], (35 kPa) above 20 psig, [1.5 BAR], (150 kPa) setpoint
  • Supply Pressure:
    250 psig, [17.0 BAR], (1700 kPa) Maximum
  • Supply Pressure Effect:
    Less than 0.5 psig, [.03 BAR], (3.4 kPa) for 100 psig, [7.0 BAR], (700 kPa) change in supply pressure
  • Output Pressure:
    150 psig, [10.0 BAR], (1000 kPa) Maximum
  • Sensitivity:
    1" (2.54 cm) Water Column
  • Ambient Temperature:
    -40°F to +200° F, (-40°C to +93° C)
  • Body and Housing:
    Die Cast Aluminum
  • Trim:
    Stainless Steel, Brass, Aluminum, and Zinc Plated Steel
  • Diaphragms:
    Nitrile on Dacron

Description

FAIRCHILD Model 200XLR Pneumatic Volume Booster

Features

  • The Model 200XLR Pneumatic Vo l u m e
    B ooster produces a pneumatic signal in a
    1:1 ratio. It is ideally suited for systems that
    require input isolation or increased fo r wa r d
    and exhaust flow capacities.
  • Control sensitivity to 1" water column va ri a t i o n
  • Large supply and Exhaust Va l ves prov i d e
    high for ward and exhaust flows
  • An Aspirator Tube minimizes downstream
    pressure droop under flow conditions.
  • A separate Control Chamber isolates the
    diaphragm from the main flow to eliminate
    hunting and buzzing
  • Optional Increased Sensitivity configura t i o n
    with larger Control Diaphragm for more
    precision control at low setpoints.
    Operating Principles

You may also like

  • FAIRCHILD M10 Pneumatic Precision Regulator
  • FAIRCHILD High Flow Precision Pressure Regulator (M100)
  • FAIRCHILD Model HPP High Pressure Precision Regulator
  • FAIRCHILD M10BP Precision Pressure Regulator