BAUMER Level Switch LFFS

  • Sensor - Radiated signal:
    100...180 MHZ
  • Sensor - Process connection:
    Hygienic: G1/2, 3-A/DN38 or sliding connection
  • Sensor - Insulating material:
    PEEK Natura
  • Housing:
    Stainless Steel, W1.4301/AISI 304
  • Process connection:
    Stainless Steel, W1.4404/AISI 316 L
  • Amb. temperature:
    -40...85 °C
  • Process temperature - Std. & 3-A/DN38:
    -40...115 °C
  • Process temperature - Sliding connection:
    -40...200 °C
  • Process temperature - < 1 hour, Tamb < 60 °C:
    -40...140 °C
  • Media pressure - Standard G½ hygienic:
    < 100 bar
  • Media pressure - 3-A DN38:
    < 40 bar
  • Media pressure - Sliding connection:
    < 16 bar
  • Vibrations:
    IEC 60068-2-6, GL test2
  • Power supply:
    12,5...36 VDC, 35 mA max.
  • Damping:
    0...10 sec.
  • Power-up time:
    <2 sec.
  • Reaction time:
    0.1 sec. (100 mS)

Description

BAUMER Level Switch LFFS

Special Features

  • Wetted parts in acid-proof, stainless steel and PEEK 
  • Compact, food compatible, hygienic design
  • Hygienic connections conform to 3-A standards, FDA demands and EHEDG guidelines 
  • Precise switching point without calibration
  • Process temperature -40...200 °C 
  • Measures media with DK-values >1.5 (DK = Dielectrical Constant)
  • Not influenced by foam
  • LED switch indicator 
  • Maintenance free 
  • Suitable for media separation measurement
  • Configurable by FlexProgrammer 9701 
  • ATEX approval for gas and dust 
  • WHG approval (leakage and overfill)